Showing results: 1636 - 1650 of 2632 items found.
-
4137 mO -
Standard Electric Works Co., Ltd
● Protection class: IP66 (Lid closed)● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.
-
781027-01 -
NI
Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The sbRIO‑9219 is designed for multipurpose testing. With the sbRIO‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel. Non-enclosed modules are designed for OEM applications.
-
Weschler Instruments
These switchboard meters and edgewise meters provide a bright, easy to read display of current, voltage, power or other process parameters. Use visible setpoints to quickly show process status. Order optional relay outputs for alarms or control. Models and sizes are available to replace most popular analog instruments. Made in USA.
-
HH2099 -
Colluck Company Limited
3-1/2 digil Large LCD display 2000 count with symbolic signs. CAT II 600V rated. Basic accuracy 0.5%. Auto Ranging High Voltage test up to 600V DC and 600V AC. Higher Current test up to 1000A AC/DC. Measure Resistance up to 20MΩ
-
CAT-H Series -
Amperis sl
The operation of the breaker can be initiated in different ways (e.g. from a control room, by a local breaker or externally by a test device) depending on the test conditions. Various time measurement triggers are available to record a measurement under a different test condition:*Coil control channel*Continuous current clamping channel*DC voltage channel
-
Osborne Transformer Corp.
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
HH2102 -
Colluck Company Limited
Basic Accuracy 1.0%. LCD display 2000 count, 12.8mm figure height. Manual Ranging at your choice (19 Range). Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 20MΩ. Signal Injection and Diode test
-
CMC 430 -
OMICRON electronics
The CMC 430 is the preferred choice for test engineers in cases where excellent transportability is needed and three currents up to 12.5 A or six voltage outputs are sufficient. Its low weight of just 8.7 kg / 19.2 lbs, and robust design with its edge protection predisposes the device to every outdoor and indoor use.
-
Ajinkya Electronic Systems
Backed by a rich industry experience, we are able to offer a wide range of Process Logger to our clients. There are various process parameters which are to be logged / recorded against time in various industries. These can be physical parameters, such as temperature, flow, pressure, humidity, level or electrical parameters, such as AC / DC voltages, currents, power parameters.
-
HH2205G -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.50%). 3-3/4 Jumbo LCD display 4000 count with symbolic signs. Double Injection Casing. Backlight for work in a dim area. High Voltage test up to 1000V DC and 750V AC. Higher Current test up to 10A AC/DC. Diode and Continuity check
-
Premier Electrosystems
The Earth Contact Resistance Tester is a basic safety test prescribed in many IS standards. The goal is to test samples for the proper connection of earthing wire with the appliance. Premier's ECR tester checks the contact resistance between accessible metal parts of the appliance and the Earth pin by passing a high current and measuring the resultant voltage drop.
-
PTE-100-C Pro -
EUROSMC, S.A.
The values which are presented in the LCD display are highly accurate, easy to read, and independent of the injection made by the PTE-100-C base unit.The display shows continuously the phase difference between the voltage and the current injected, and can be adjusted during the test with an accuracy of 0.1º. This facilitates the test for directional relays or reclosers and synchronizing relays, etc.
-
Laser Components IG, Inc.
PIN photodiodes convert light to current – without a bias voltage having to be applied. Silicon is commonly used as an inexpensive detector material in the Vis range. For higher demands, InGaAs is used; it covers the widest spectral range from the Vis to the NIR. We offer silicon carbide as a “solar-blind” detector specifically for the UV range.
-
SY3632 -
Hong Kong Songyang Industrial Ltd.
The SY3630 Energy Meter Testing Instrument is used to calibrate three phase, single phase, active or reactive energy meter under work, and also it can be used as voltage, current and power meter to measure AC parameter of three phase power line. Same as ZERA and MTE. Of course our price is very reasonable.
-
40-614B-016 -
Pickering Interfaces Ltd.
This 1-bank, 64-channel, 2-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.